Calculates usable storage capacity for common RAID configurations from the number and size of drives used.
Variables
| Symbol | Quantity | Unit |
|---|---|---|
| Usable Capacity | Total usable storage | TB |
| N | Number of drives | |
| S | Capacity of each drive | TB |
What it means
RAID (Redundant Array of Independent Disks) configurations provide different trade‑offs between performance, capacity, and redundancy. The usable storage capacity depends on the RAID level. RAID 0 (striping) uses all disks for data, giving capacity = N × S (total raw capacity), but no redundancy. RAID 1 (mirroring) duplicates data across two disks, so capacity = S (only one disk worth). RAID 5 (block‑level striping with parity) uses one disk worth of parity across N disks, so capacity = (N−1) × S, tolerating a single disk failure. RAID 6 uses two parity disks, capacity = (N−2) × S. These formulas are essential for storage planning, cost estimation, and designing fault‑tolerant systems. In practice, the usable capacity may be slightly less due to overhead and formatting. Understanding these capacities helps in choosing the right RAID level for performance, availability, and budget. The formula is widely used in server and data center design.
Worked example
RAID Storage Capacity – Two Examples
Real‑World| Parameter | Value |
|---|---|
| N (drives) | 4 |
| S (size per drive) | 2 TB |
| RAID 5 capacity | (N−1) × S = 3 × 2 = 6 TB |
| Parameter | Value |
|---|---|
| N (drives) | 6 |
| S (size per drive) | 4 TB |
| RAID 10 capacity | (N/2) × S = 3 × 4 = 12 TB |
Common mistakes
- RAID levels: The formula given is for RAID 0, RAID 1, and RAID 5 only. Other levels (e.g., RAID 6, RAID 10) have different capacity formulas.
- N disks: N is the total number of disks in the array.
- S size: S is the capacity of a single disk (all disks assumed equal).
- RAID 5 parity: One disk worth of capacity is lost to parity, so usable = (N−1)×S.
- Hot spare: If a hot spare is included, it does not contribute to usable capacity.
Applications
RAID (Redundant Array of Independent Disks) usable capacity depends on the RAID level: RAID 0 gives N×S (all disks for data), RAID 1 gives S (mirrored), and RAID 5 gives (N−1)×S (one disk for parity). This capacity calculation is essential for storage system design, balancing performance, redundancy, and cost. Engineers use these formulas to choose the appropriate RAID level for database servers, file servers, and backup systems. RAID 0 provides maximum capacity and performance but no redundancy; RAID 1 offers fault tolerance at lower capacity; RAID 5 balances both. Understanding these capacities helps in planning storage arrays, estimating usable space, and ensuring data protection.
- Design of storage arrays for servers
- Database and file server capacity planning
- Data protection and disaster recovery strategies
- Performance optimisation with RAID levels
- Cost‑benefit analysis of storage solutions