Biot–Savart Law

This law tells you how much magnetic field a tiny piece of current-carrying wire creates at any point in space. Imagine a small segment of wire as a tiny magnet: the field it produces depends on the current, the length of that segment, the angle, and how far away you are. The closer you get, the stronger the field. It is the building block for calculating magnetic fields of complex wire shapes by adding up contributions from all the small pieces.

Magnetics Magnetostatics
Magnetic Field Element

Biot–Savart Law Calculator

The Biot–Savart law gives the magnetic field produced by a small piece of current-carrying wire. Calculate the field of a single current element, or of a straight wire or a circular loop, which come from adding up many elements.

dB = (μ₀/4π) · (I·dl × r̂) / r²

Inputs

Choose the calculation, then drag a slider or type an exact value. Results update as you drag. The sliders are logarithmic, so one drag covers small and large values. Valid for steady currents in vacuum or air.

Presets

Results

Enter values and press Calculate.

Field diagram

Press Calculate to draw the diagram.

Reference tables

Common examples (illustrative values, computed by the same engine)

CaseShapeFieldIn µT

Formulas from the Biot–Savart law

ShapeField
Current elementdB = (μ₀/4π) · I · dl · sin θ / r²
Infinite straight wireB = μ₀ I / (2π d)
Straight wire of length L, centred on the perpendicularB = (μ₀ I / 2π d) · (L/2) / √((L/2)² + d²)
Circular loop, on its axisB = μ₀ N I R² / ( 2 (R² + z²)3/2 )
Circular loop, at its centreB = μ₀ N I / (2R)
Far from a loop (z ≫ R)B ≈ μ₀ m / (2π z³), with m = N I π R²

Typical magnetic fields (approximate)

SourceFlux density
Earth's field at the surface25 – 65 µT
Long wire carrying 10 A, at 5 cm40 µT
Small fridge magnetabout 5 mT
Strong neodymium magnet, at the surface0.2 – 0.5 T
Clinical MRI scanner1.5 – 3 T

Key relations and units

QuantityRelation
Vacuum permeabilityμ₀ ≈ 4π × 10⁻⁷ T·m/A = 1.2566 × 10⁻⁶ T·m/A
Constant in the lawμ₀ / 4π ≈ 10⁻⁷ T·m/A
DirectiondB points along dl × r̂ (right-hand rule)
Magnetic field units1 T = 1000 mT = 10⁶ µT = 10⁹ nT = 10⁴ G

Formula and notes

dB = (μ₀/4π) · (I·dl × r̂) / r²
|dB| = (μ₀/4π) · I · dl · sin θ / r²
  • I: current in the wire, and dl: the length of the small element, pointing along the current
  • r: distance from the element to the point; r̂: the unit vector pointing from the element to the point
  • θ: angle between dl and r̂; the field is largest at 90° and zero along the line of the element

Example. A 1 mm element carrying 10 A, seen from 10 cm away at 90°: dB = 10⁻⁷ × 10 × 0.001 × 1 / 0.1² = 1 × 10⁻⁷ T = 100 nT.

Wire example. A long straight wire carrying 10 A has B = μ₀ I / (2π d) = 2 × 10⁻⁷ × 10 / 0.05 = 40 µT at 5 cm. Loop example. One turn of radius 10 cm carrying 1 A has B = μ₀ I / (2R) = 6.28 µT at its centre.

A single current element cannot exist alone, because steady currents flow in closed loops. The real field is the sum, or integral, of the contributions of every element, and the straight wire and loop modes do that sum for you. The element mode assumes the element is small compared with the distance (dl ≪ r). The straight-wire mode puts the point opposite the middle of the wire. The results assume vacuum or air, with no magnetic materials nearby.

Disclaimer. For education and estimation. Magnetic field safety limits and equipment design need proper measurements and a qualified engineer.

References

Variables

Symbol Quantity Unit
B Magnetic flux density (total field at point) T
μ₀ Permeability of free space (4π×10⁻⁷) H/m
I Electric current in the conductor A
R Radius (of circular loop) or perpendicular distance (to wire) m
L Length of straight wire segment m
z Distance from center along axis of loop m

What it means

The Biot–Savart law calculates the magnetic field contributed by a small current element I·dl. The field dB is given by dB = (μ₀/4π) * (I dl × r̂) / r². It is used to find the magnetic field produced by arbitrary current distributions by integrating over the current path. This law is more general than Ampere’s law (which works for symmetric cases). It is essential for calculating the magnetic field of loops, coils, and any complex wire shape. In practice, it is used in the design of electromagnets and magnetic sensors. Example: For a short segment of wire carrying 1A, the field at a distance of 0.1m perpendicular to the segment is dB = (4π×10⁻⁷/4π) * (1 * 0.01) / 0.01 = 10⁻⁷ * 1 = 10⁻⁷ T, but this is a small contribution; the total field requires integration over the entire wire.

Worked example

Biot–Savart Law – Practical Example

Real‑World
Scenario: A circular loop of radius 0.05 m carries 5 A. Find the magnetic field at the centre.
ParameterValue
I5 A
R0.05 m
μ₀4π×10⁻⁷ H/m
FormulaB = (μ₀·I) / (2·R)
1Substitute: B = (4π×10⁻⁷ × 5) / (2 × 0.05)
2Compute: B = (6.283×10⁻⁶) / 0.1 = 6.283×10⁻⁵ T
Final Design B ≈ 62.8 µT ✓ Loop centre field
Why: The Biot–Savart law gives the magnetic field produced by a current element – integrating over a loop gives the centre field.

Common mistakes

  • Current element: I·dl – a vector along the current direction.
  • Vector nature: The magnetic field is a vector – cross product with r̂ gives direction.
  • Units: dB in teslas.
  • Superposition: Integrate over the entire current distribution to get total B.
  • Assumption: Valid for steady currents (magnetostatics).

Applications

Biot–Savart law calculates the magnetic field contribution from a small current element, integrating to find the total field for any current distribution. This is used to compute magnetic fields of complex geometries, such as coils and solenoids, which are essential for designing inductors, magnetic sensors, and MRI machines. Engineers apply it to optimise the field uniformity in magnets and to design magnetic recording heads. By using the Biot–Savart law, they can predict the magnetic field with high accuracy, guiding the placement of windings and ferromagnetic materials. This law is crucial for electromagnetics and magnetic device design.

  • Design of coils, solenoids, and magnetic sensors
  • Magnetic field optimisation in magnets and inductors
  • Magnetic recording head design
  • MRI and NMR magnet design
  • Educational understanding of magnetic field sources